Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Approval
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T11CM02699
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Partial Approval
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/27/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TOP OUT FRONT AREA | |
| 09/27/2012 | REINFORCED MASONRY PRE-GROUT | Approved | ||
| 09/20/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL PROGRESS FRONT AREA OK VARIOUS HEIGHTS | |
| 09/17/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BEAM SETS OK FRONT AREA | |
| 09/12/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 09/11/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 09/10/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | PROGRESS FRONT AREA OK ( VARIES 8' TO 12')) | |
| 09/10/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 08/29/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TOP OUT MAIN BUILDING | |
| 08/24/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Vertical reinforcement on line F should extend 2/3 into the top course of block or bond beam. Provide RFI response from engineer for repair. | |
| 08/21/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BEAM SET OK AT EAST WALL. OTHER INFILL WORK OK. | |
| 08/20/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | MISSING 2 #6 DRAG BARS IN EAST WALL ALL OTHER PROGRESS OK |
|
| 08/14/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL PROGRESS OK.....WILL NEED WELDABLE REBAR AT BEAM SEAT | |
| 08/08/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | PROGRESS ON WEST AND NORTH WALLS OK, PLUS SOME SMALL AREA ON EAST WALL | |
| 08/07/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 08/06/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL BUILD PROGRESS OK. NEAR TOW ON WEST SIDE, VARIOUS HEIGHTS OTHER AREAS. | |
| 08/02/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 20' WEST WALL & ALL OTHER PROGRESS OK PROVIDE RFI FOR TERMINATING CONTROL JOINT FOR NEW END OF WALL CONDITION |
|
| 07/31/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL PROGRESS OK | |
| 07/30/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 07/27/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL PROGRESS OK. NEED TO CLARIFY (REVISE) HOW TO MAKE PLATE ATTACHEMENT AT 23' FOR OCS...DETAILS SHOW MASONRY EMBED BUT MASONRY STOPS AT 22' | |
| 07/20/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | all progress ok | |
| 07/19/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 07/18/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL PROGRESS OK. OK TO GROUT TO LINTEL HEIGHT AT EAST DOORWAY | |
| 07/11/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | T.O.W MOST OF LINE K | |
| 07/06/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LINE K 16' LAID UP BUT REIFORCEMENT NOT YET INSTALLED | |
| 07/05/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LINE K 12' | |
| 07/03/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 8' | |
| 06/29/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ALL PROGRESS OK | |
| 06/26/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 06/22/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 7/F-G & G/4-7 & F/3-7 TO FFE OK WHEN SPECIAL INSP CONFIRMS FINAL CORRECTIONS |