Permit: T11CM02649

Parcel: 124131480


Addresses:

1140 E 15TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/05/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/30/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BEDROOM 2 HEADER 2-2 X 8 H-11
2) CHECK SW-4 NAILING 6" ON CENTER ALL EDGES
3) NAIL DBL STUDS AT BEDROOMS 6" ON CENTER BOTH STUDS
4) BEDROOM 1 HEADER-6
5) KITCH 2-2 X 6 STUD AT ALL TOP PLATE JOINTS
6) STOPPED INSPECTION
11/22/2011 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) EXPOSE SW-5 KITCHEN WALL FOR INSPECTION
2) MISSING HOLDOWNS AT STORAGE WITH DBL STUDS
3) ALL HOLDOWNS MUST BE INTO DBL STUD RETRO FIT HOLDOWN AT MASTER BEDROOM
4) CHECK ALL SHEARWALL NAILING
10/06/2011 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PROVIDE AS BUILT TO CARPORT TOOF FRAMING PLAN FROM LIGHT STEEL JOISTS TO 2X8. PROVIDE LEDGER DETAIL OR BUILD TO PLAN
CARPORT ROOF NAILING OK
2) INSPECTION TO KITCHEN SW-5 & CARPORT WALLS OK TO COVER