Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T11CM02636
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/16/2013 | PLUMBING - INTERMEDIATE | Approved | ||
01/28/2013 | PLUMBING - INTERMEDIATE | Partial Approval | master bedroom/family room mech room | |
12/18/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
11/20/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
06/13/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PROVIDE AS BUILT PLANS REFLECTING CHANGES TO PLANS OK TO BACKFILL ALL PLUMBING AND ELECTRICAL IN TRENCHES |
|
05/07/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK TO BACKFILL 20' OF TRENCH FROM J-BOXES PANEL D 2) CHECKED SHOWER DRAIN, OK TO BACKFILL |
|
05/03/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) TEST ON SOFT WATER PIPING IN TRENCH OK 2) OK TO BACKFILL UP TO POOL SUPPLY LINE. LEAVE OPEN FOR POOL ELECTRIC 3) 15 PSI TEST ON FIREPLACE GAS LINE OK , SHOWER DRAIN LEAKING 4) DUCT ABOVE ATTIC INSULATION TO BE R8 5) NEED TO SEE GAS ISOMETRIC DRAWING FOR GAS LINE TO FIREPLACE 6) BACKFILL GAS LINE AT YOUR OWN RISK 7) YARD WATER LINE OK |
|
03/22/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) BATH #1 EXCEPT SHOWER DRAIN, BATH #2 EXCEPT SHOWER DRAIN 2) NEED TO COMPLETE STAIC LINE TESTS FOR SHOWERS |