Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2012 | MECHANICAL - INTERMEDIATE | Approved | ||
| 08/30/2012 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 07/31/2012 | MECHANICAL - INTERMEDIATE | Partial Approval | POOL AND GREAT ROOM OK | |
| 07/27/2012 | MECHANICAL - INTERMEDIATE | Denied | 1) JUNCTION BOXES CAN NOT BE BURIED IN WALL 2) OUTLET SPACING 6' FROM OPENING 3) GROUND METAL BOXES 4) SHEATHING TO EXTEND 1/4" INTO BOX AND PANEL 5) MISSING HALL CAN 6) RETURN AIR NOT AS PLANS 7) MISSING CLIP FOR RAFTER SITTING ON TOP OF PARTITION WALL 8) GAS LINE OPEN NO PRESSURE |
|
| 07/24/2012 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 12X10 RETURN AIR MISSING PER PLAN |