Permit: T11CM02522

Parcel: 137281130


Addresses:

821 W WEDWICK ST

Inspection Status: Denied

Inspection History: FRAMING

Date Description Inspector Results Comments
08/26/2011 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRONT PORCH EXPOSE FOOTERS TO VERIFY
2) MISSING LEDGER BOLTS PER PLAN
3) 4 X 8 HEADER OVER SPANNED, INSTALL POST
FAMILY ROOM:
1) PROVIDE LETTERHEAD FROM LICENSED ELECTRICIAN STATING WORK TO FAMILY ROOM TO CODE FOR SAFETY AND DOES NOT POSE HAZARD
2) EXPOSE RAFTER TO BEARING WALL CONNECTION TO PLAN
REAR PORCH:
1) EXPOSE FOOTERS
2) GAS LINE UNDER SLAB REAR PORCH
3) CARPORT, FAMILY ROOM AND PORCHES ON PROPERTY LINES
4) SUBMIT ON PLAN ALL NECESSARY FIRE SEPERATIONS TO INCLUDE