Permit: T11CM02490

Parcel: 141352970

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T11CM02490

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/29/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/28/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 1/2" DIA. ANCHOR BOLTS 24" ON CENTER FOR #4 SHEAR
2) 1/2" DIA. ANCHOR BOLTS 32" ON CENTER FOR #3 SHEAR
3) 503 STRAP DETAIL PER PLAN (2 STRAPS)
4) 1/2" DIA. ANCHOR BOLT 12" ON CENTER FOR #6 SHEAR
5) SHIM BEARING OF F2 FLOOR TRUSS
6) 5/8 SD MISSING FOR 5 BAYS
7) NAIL OFF BRACE BLOCKS PER 413 DETAIL