Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T11CM02490
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/29/2011 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
09/28/2011 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 1/2" DIA. ANCHOR BOLTS 24" ON CENTER FOR #4 SHEAR 2) 1/2" DIA. ANCHOR BOLTS 32" ON CENTER FOR #3 SHEAR 3) 503 STRAP DETAIL PER PLAN (2 STRAPS) 4) 1/2" DIA. ANCHOR BOLT 12" ON CENTER FOR #6 SHEAR 5) SHIM BEARING OF F2 FLOOR TRUSS 6) 5/8 SD MISSING FOR 5 BAYS 7) NAIL OFF BRACE BLOCKS PER 413 DETAIL |