Permit: T11CM02488

Parcel: 141354280

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T11CM02488

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/23/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/22/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL OFF PATIO LEDGER PER 308/SD
2) (2) CS16 X 48 AT GARAGE OVERHEAD 16' PER PLAN
3) (2) KING STUDS NEEDED AT FRONT WINDOW AND BACK BEDROOM WINDOW
4) SHIM INTERIOR BEARING AT FLOOR TRUSSES
5) 3 2 X 4 POST NORTH END OF BEAM IN 1ST FLOOR HALLWAY
6) NAILS MISSING NORTH WEST CORNER OF HOUSE IN ROOF SHEATHING