Permit: T11CM02444

Parcel: 12302141A


Addresses:

2807 E SENECA ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/18/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
08/11/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PANEL AND PANEL CLAMPS MAY SECURE TO ROOF WITH BOLTS, BUT SUPPLY AND RETURN PIPING REQUIRES SUPPORT ABOVE ROOF WITH MINIMUM 1 1/2" OF CLEARANCE
2) PATCH SCREW HOLES IN ROOF AND PROVIDE WEATHER RESISTANT SUPPORTS
3) PROVIDE ISOLATION BETWEEN PIPE AND UNISTRUT CLAMPS TO ALLOW FOR EXPANTION CONTRACTION