Permit: T11CM02424

Parcel: 112041660

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
09/27/2011 MECHANICAL - FINAL Approved IVRS - Inspection :*
08/24/2011 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL TITE NOT APPROVED AS CONDENSATE DRAIN
2) ROMEX NOT TO BE RUN IN CONDUIT PER N.E.C. PROVIDE THNN OR OTHER APPROVED WIRING
3) WHITE WIRING NOT TO BE USED AS A NOT LET
4) TWO WIRES CANNOT BE LANDED AT A SINGLE LUG. PROVIDE SEPERATE BREAKER.
5) PROVIDE SERVICE OUTLET AT NEW CONDENSER (WITHIN 35')
60 PROVIDE MEANS OF DISCONNECT AT INDOOR UNITS.
08/17/2011 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*