Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM02346

Parcel: 126111200


Addresses:

4456 E ELMWOOD ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
08/08/2011 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
08/02/2011 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VENTING NOT INSTALLED CORRECTLY
2) CONDENSATE PIPING NOT INSTALLED CORRECTLY
3) CONTRACTOR TO BE ON SITE AT NEXT INSPECTION
07/28/2011 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection IVRS - Inspection :*
1) FLUE INSTALLED BACKWARDS
2) REMOVE ALL TAPE AND DUCT SEALER FROM FLUE PIPE
3) ALL PVC PIPE TO HAVE PRIMERED JOINTS, PRIMER IS TO BE PURPLE IN COLOR
4) PROVIDE SECONDARY DRAIN AT EVAP ?
5) LINE SET NOT PROPERLY INSTALLED
6) CONDENSATE PUMP SAFETY NOT WIRED
7) PROVIDE RUBBER GROMMETS AT LINE SETS ENTERING COIL
8) LINE SET INSULATION TO BE COATED PER MANUFACTURERS INSTALLATION INSTRUCTIONS
9) OUTDOOR UNIT OVER FUSED
10) PROVIDE AN APPROVED WATER TIGHT ENCLOSURE FOR OUTDOOR J-BOX AND PLUG HOLE IN DISCONNECT
11) T-STAT TO BE IN CONDUIT OUTDOORS
12) UNIT NOT PROPERLY SEALED UNIT TO COIL