Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T11CM02290
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2011 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
10/18/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) INSULATE AND SUPPORT ABOVE CEILING 2) RECALL FOR DEMO |
|
10/14/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) ABS NOT READ 2) PEX TUBING NOT SECURED AND NOT INSULATED |
|
10/13/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) DO NOT USE A HOSE WITHOUT A VACUUM BREAKER TO FILL DWV 2) A BLAKE TEE MAY BE INSTALLED HORIZONTALLY 3) A CLEANOUT SHALL OPEN ABOVE FLOW LEVEL 4) PROVIDE A TEST AND STRAP & SECURE ALL PIPING 5) OK TO INSULATE TUBING 6) IECC CODE REQUIRES 1" THICK INSULATION ON ALL RECIRCULATING HOT PIPING 7) PLAN SPECIFIES LAV CARRIERS |