Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM02288

Parcel: 12217365A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
11/30/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
11/28/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
UPPER RESTROOM:
1) TRAP AND TRAP ARM TO BE THE SAME SIZE-TRAP ARM MAY NOT CHANGE SIZE. TRAP MAYBE ONLY ONE PIPE SIZE LARGER FROM THE TAIL PIECE TO WHICH IT IS CONNECTED
2) CHECK GRADE OF ALL PIPING, BACK PITCH NOT PERMITTED
3) PLAN CALLS FOR TYPE "K" COPER UNDER SLAB
4) REMOVE ALL ROCKS, CALICHI, CONCRETE AND DEBRIS FROM TRENCH
5) REDO OR SEAL #5 BREAKS DOWN ABS ADN MAY NOT BE USED
LOWER RESTROOM:
1) SOILS TO WET FOR INSPECTION
2) NEED TO COMPLETE DEMO AT EXISTING SINK
3) CONNECTION TO BLDG SEWER OK
11/23/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection COULD NOT LOCATE BLDG 4 AT 1550 N COUNTRY CLUB.
BLDG THAT MAY BE #4 HAS NO SUITE 4101