Permit: T11CM02238

Parcel: 128140470


Addresses:

5256 E 17TH ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/15/2011 BUILDING - FINAL Approved IVRS - Inspection :*
08/29/2011 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TEMPERATURE AND PRESSURE RELIEF DRAIN TO TERMINATE 24" MAX FROM FINISH GRADE TO PREVENT SCALDING
2) PROVIDE 6" MINIMUM CLEARANCE FROM SINGLE WALL VENT CONNECTOR AND COMBUSTIBLE INSULATION
3) SEAL POTABLE WATER PIPING ON EXTERIOR OF ENCLOSURE INSULATION TO PROTECT FROM FREEZING
4) PROVIDE MINIMUM 1" CLEARANCE FOR DBL WALL VENT THRU ROOF AND COMBUSTIBLE WOOD ROOF STRUCTURE
5) PROVIDE LADDER ON SITE FOR ROOF TOP INSPECTION AS REQUIRED AT ALL SITES
6) LIST NOT COMPLETE
7) CONTRACTOR TO PAY REINSPECTION FEE PRIOR TO FINAL