Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM02231

Parcel: 114540480

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
10/14/2011 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
09/29/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) OK TOP OUT AT ALL GARAGE WALLS TO GROUT
09/26/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) OK 2ND LIFT AT GARAGE NORTH WALL
09/20/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) OK 1ST LIFT AT 4' TO GROUT