Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/12/2012 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/13/2011 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/06/2011 | FRAMING | Partial Approval | IVRS - Inspection :* 1) MISSING BEAM HANGER @ HOSE 2) FHA STRAP U&E HEADER TO EXISTING POST EAST SIDE 3) PROVIDE BEAM TO POST ATTACHMENT @ RIDGE BEAM 4) MINIMUM 3-16 D NAILS @ LEDGE OVER ENTRY DOOR |