Permit: T11CM02109

Parcel: 105110690

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Permit Number - T11CM02109

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
12/05/2011 PLUMBING - PROGRESS Approved IVRS - Inspection :*
11/16/2011 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
1) SUPPORT VERTICAL ABS
2) ISOLATE ABS FROM METAL STUDS
3) SUPPORT ABS AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN 4' BETWEEN HANGERS
4) ABS WATER TEST THRU ROOF OK
11/08/2011 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) PIPING TO BE INSULATED PER PLUMBING SPECS
2) PIPING TO BE LABELED PER GENERAL PLUMBING NOTES