Inspection History Details
Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
Permit Number - T11CM02031
Inspection Description - MECHANICAL - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE GAS PIPING DIAGRAM APPROVED BY CITY OF TUCSON 2) PROVIDE GAS PRESSURE TEST 3) CONDENSATE NOT PROPERLY INSTALLED, THIS IS A TRIP HAZARD, DO NOT RUN PIPING ALONG WALKWAY 4) FLEX DUCT IS TO BE STRAPPED UP A MINIMUM OF 6" ABOVE GROUND UNDER TRAILER 5) WHITE WIRE NOT TO BE USED AS A HOT LEG 6) ALL PVC JOINTS ARE TO BE PRIMERED |