Permit: T11CM01965

Parcel: 129063640


Addresses:

2414 E BEVERLY DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/22/2012 PLUMBING - FINAL Approved IVRS - Inspection :*
12/19/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
12/16/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) T & P RELIEF DRAIN DOES NOT COMPLY WITH NOTE #1 FROM 10/18/11
2) FLOOR UNDER WATER HEATER IS WET
3) SHOW HOW WIRING FOR G.F.I. IS IN AN APPROVED RACEWAY
10/18/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER HEATER T & P TO GRAVITY DRAIN TO EXTERIOR TERMINATE AT DOWNWARD ANGLE
2) PROVIDE DEDICATED OUTLET OR GFCI PROTECTION FOR PUMP OUTLET CIRCUIT. PROPERLY WIRED AND WIRING IN APPROVED RACEWAY
3) WATER HEATER VENT CONNECTOR TO BE FREE OF HOLES AND HAVE 6" CLEARANCE FROM ALL COMBUSTIBLE MATERIALS
4) WATER HEATER VENT TO BE EXTENDED WITH DBL WALL VENT PIPE TO 3' ABOVE TOP OF AIR INTAKE, WHEN WITHIN 10' OF INTAKE
5) PIPING ON ROOF CANNOT BE J-HOOKED INTO ROOF SURFACE
6) REMOVE THE TAPE AT SINGLE TO DBL WALL VENT CONNECTION AND VERIFY CORRECT MAKE UP