Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T11CM01946

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/18/2011 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
11/17/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/15/2011 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE ABS COMBOS-INSTALL PVC AS SPECIFIED
2) PROVIDE 1/4" PER FOOT SLOPE ON DRAIN PIPING
3) BACKFLOW ASSEMBLY IS SPECIFIED FOR COOLERS ONLY, NOT FOR OTHER WATER PIPING. PROVIDE TEST REPORT AFTER CORRECTING INSTALLATION
4) CORRECT LINE SIZE AS SHOWN ON YOUR PLAN
5) REMOVE EXCESS FLUX FROM COPPER JOINTS, ALL JOINTS SHALL BE DEBURRIED AS REQUIRED BY CODE
6) FAILURE TO COMPLY MAY RESULT IN REINSPECTION FEES
11/10/2011 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*