Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/17/2011 BUILDING - FINAL Approved IVRS - Inspection :*
07/08/2011 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE NOTE #2 FROM 6/20/11 INSPECTION HISTORY
2) CONTRACTOR TO PAY REFEE PRIOR TO FINAL
NOTE: PEX TUBING IS CONSIDERED COMBUSTIBLE UNLESS YOU CAN PROVIDE LISTING VERIFYING OTHER WISE
06/20/2011 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE RIDGID FULL SIZE PIPING FOR T & P RELIEF DRAIN (NO FLEX)
2) PROVIDE 6" MINIMUM CLEARANCE FROM SINGLE WALL VENT CONNECTORS AND COMBUSTIBLE MATERIALS, LIKE INSULATION
3) WATER HEATER VENT TO BE DBL WALL TO 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE WITH APPROVED DBL WALL VENT CAP