Permit: T11CM01745

Parcel: 130055480


Addresses:

2515 S PLUMER AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/26/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/07/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CONDENSATE NOT TO TERMINATE ON HARD SURFACE
2) CLEAR POLY TUBING NOT TO BE USED ON EXTERIOR
3) LINE SET INSULATION IS TO BE COATED FOR U.V. PROTECTION ON EXTERIOR, DUCT TAPE NOT APPROVED MATERIAL
4) T-STAT AT WIRE IS TO BE IN PROTECTIVE CONDUIT ON EXTERIOR
5) BREAKER DOES NOT PROPERLY FIT IN PANEL, PROVIDE SQUARE D BREAKER
6) ALL PVC IS TO HAVE PRIMERED JOINTS, PRIMER IS TO BE PURPLE
7) PROVIDE SECONDARY DRAIN AT EVAP COIL
8) CORD CONNECTORS ARE TO BE TIGHT AND SECURE
9) GAS FLEX NOT TO BE RE-USED, PROVIDE NEW GAS FLEX