Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PRE SLAB
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2013 | PLUMBING - PRE SLAB | Approved | IVRS - Inspection :* | |
| 01/30/2012 | PLUMBING - PRE SLAB | Partial Approval | IVRS - Inspection :* | |
| 01/27/2012 | PLUMBING - PRE SLAB | Partial Approval | IVRS - Inspection :* 1) REINSPECTED 2:15 PM 2) CORRECTION MADE OK 3) OK TO COVER FINES SEPERATION TANK DRAIN |
|
| 01/26/2012 | PLUMBING - PRE SLAB | Not ready for Inspection | FIRE SEPERATION TANK: 1) VERIFY THAT 4" PVC IS TIED INTO RECLAIMED WASTE 2) PVC TO BE LAID ON A FIRM BASE, BRIDGING NOT PERMITTED 3) INLET PIPING NOT RUN 4) TANK NOT SET 5) NO PROVISION MADE FOR A VENT DOWNSTREAM OF THE TANK 6) HORIZONTAL CHANGE OF DIRECTION EXCEEDING 135 DEGREE TO HAVE AN ADDITIONAL CLEANOUT 7) NOTE: PVC MAY NOT BE USED IN EXPOSED EXTERIOR LOCATIONS 8) PLANS, PERMIT AND INSPECTION HISTORY TO BE ON SITE AT ALL TIMES |
|
| 10/26/2011 | PLUMBING - PRE SLAB | Partial Approval | IVRS - Inspection :* 1) SEE NOTE FROM 10/12/11 INSPECTION |