Permit: T11CM01744

Parcel: 140280170


Addresses:

2209 E GINTER RD

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/14/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) TRENCH DRAINS INSTALLED OK
2) OK FOR CONCRETE
12/12/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) SOILS TO WET FOR INSPECTION
10/12/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) WATER TEST ALL UNDERGROUND PIPING PER REVISED SHEET P.1.0 DATED 10/6/11 PAUL ERICHEIN ENGINEER TO BE CITY APPROVED. WILL REQUIRE TEST ON TRENCH DRAINS AND CONNECTION TO THEM
09/28/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) 6" SANITARY DRAINAGE THRU BLDG ONLY WATER TEST THRU CLEANOUT. PROVIDE DETAIL FOR RECLAIMED DRAINAGE TD-B IF DIFFERENT FROM APP. PLAN OR INSTALL PER PLAN. PROVIDE DETAIL FOR TD-C FOR NEED OF P-TRAP AS INSTALLED. RECLAIMED TRUNK PIPING WATER TEST. RECLAIMED HAS ADDITIONAL 3" PIPING REQUIRES MINIMUM RED LINE AND APP. PLANS
2) (3)-2" STUB UPS TIEING INTO 6" AT CLEANOUT AT NORTH EAST CORNER REQUIRES DETAILS FOR SANITARY DRAINAGE AND CITY APP. PLANS. PROVIDE STAMPED SEALED LETTER FOR CELLULAR CORE PVC IN PLACE OF SPEC