Permit: T11CM01737

Parcel: 133261830


Addresses:

8102 E 3RD ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/14/2011 BUILDING - FINAL Approved IVRS - Inspection :*
06/30/2011 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE SUPPORTS ON PIPING, ALSO SUPPORT TUBING
2) SEAL JOINTS OF PIPE INSULATION WITH ADHESIVE AS SPECIFIED BY MANUFACTURER, PROTECT FROM U.V.
3) PROVIDE ACCESS TO ROOF, NAILING TO ROOF IS NOT ALLOWED, PROVIDE SUPPORTS
4) COMPLETE PETITION OF APPEAL FOR ALTERNATE RELIEF DRAIN
5) CORRECT VENT CONNECTION AT COMMON TEE
6) PROVIDE COMBUSTION AIR AND COMPLY WITH ALL REQUIREMENTS FOR GAS FIRED APPLIANCES IN BEDROOM 1PC 303.3