Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T11CM01727
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/04/2011 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
07/27/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) ALL ROOF PENETRATIONS TO HAVE ROOF JACKS 2) SERVICE OUTLET NOT PROPERLY WIRED, PULL A SEPERATE CIRCUIT 3) PVC PIPE BRACING NOT TO EXCEED 4' HORIZONTAL 4) PROVIDE GAS PRESSURE TEST 5) GAS LINE TO BE PIPE NOT FLEX PER PLAN |
|
07/26/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* |