Permit: T11CM01723

Parcel: 11702274A


Addresses:

514 E 1ST ST #02


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T11CM01723

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/21/2011 FRAMING Approved IVRS - Inspection :*
10/13/2011 FRAMING Partial Approval IVRS - Inspection :*
1) FRAMING PARTIAL UNTIL ALL INTERMEDIATES PASS
2) CAULK MESH FOAM AT WOOD PROTRUSIONS-IE. PORCH BEAMS AND SIDE LIGHT WINDOWS
3) NEED SECONDARY CONDENSATE DRAIN OR AUTO SHUT OFF DEVICE
4) SHOW SPECS THAT ALLOW RUBBER CONNECTORS ON FLUE PIPES OR CHANGE TO SOLID PVC FITTINGS
5) FIREPLACE DBL WALL FLUE NEEDS 1" TO COMBUSTIBLES AT OSB AND FRAME AT ROOF LINE
6) INTERMEDIATE PLUMBING REQUIRES DWV TEST ON ALL ABOVE GRADES ABS
09/06/2011 FRAMING Not ready for Inspection IVRS - Inspection :*