Inspection History: FRAMING
Permit Number - T11CM01723
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/21/2011 | FRAMING | Approved | IVRS - Inspection :* | |
10/13/2011 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FRAMING PARTIAL UNTIL ALL INTERMEDIATES PASS 2) CAULK MESH FOAM AT WOOD PROTRUSIONS-IE. PORCH BEAMS AND SIDE LIGHT WINDOWS 3) NEED SECONDARY CONDENSATE DRAIN OR AUTO SHUT OFF DEVICE 4) SHOW SPECS THAT ALLOW RUBBER CONNECTORS ON FLUE PIPES OR CHANGE TO SOLID PVC FITTINGS 5) FIREPLACE DBL WALL FLUE NEEDS 1" TO COMBUSTIBLES AT OSB AND FRAME AT ROOF LINE 6) INTERMEDIATE PLUMBING REQUIRES DWV TEST ON ALL ABOVE GRADES ABS |
|
09/06/2011 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |