Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T11CM01715

Parcel: 110120960


Addresses:

5301 E GRANT RD


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T11CM01715

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
03/25/2013 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
01/28/2013 EXCAVATION/LAYOUT REBAR & ZON Partial Approval 5 SHADE STRUCTURE COLUMNS OK TO POUR PROGRESS AREAS
01/18/2013 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :* CIRCULAR PLANTER WALL- AS PER DETAIL #4, PAGE LD-3 OK TO POUR PROGRESS AREA
01/03/2013 EXCAVATION/LAYOUT REBAR & ZON Partial Approval STEM WALL FOOTING SOUTH PAVILLION AREA OK TO POUR
12/28/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval SITE WALL FOOTING AT PAVILLION ENTRY AREA COLUMN FOOTINGS AT BEVERLY STREET ENTRANCE -OK TO POUR PROGRESS AREAS
12/26/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*4 LIGHT POLE CAISSON FOOTINGS- OK TO POUR PROGRESS AREAS
11/09/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval FOOTING FOR MONUMENT WALL; EAST OF AMBULANCE ENTRANCE- OK TO POUR PROGRESS AREAS
10/20/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval STEM WALL FOOTINGS- AT EMERGENCY ROOM ENTRY AREA OK TO POUR PROGRESS AREAS
10/17/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval PERMISSION GIVEN TO PLACE FOOTINGS FOR SMALL (<2') RETAINING WALLS WITHOUT INSPECTION.
10/05/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval MAIN ENTRY SITE WALL (EAST-LOW PORTIONS) OK TO POUR PROGRESS AREAS
10/03/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval MAIN ENTRY (EASTSIDE) MONUMENT WALL- TALL SECTIONS (2) AT 70"-OK TO POUR PROGRESS AREAS
09/27/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval SCREEN FOOTINGS-MAIN ENTRY (EAST SIDE) DETAIL #D PAGE S19-OK TO POUR PROGRESS AREA
09/24/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval 7 LIGHT POLE CAISSON FOOTINGS- 3 MAIN ENTRY - EASTSIDE 4 AT EMERGENCY AREA- OK TO POUR PROGRESS AREAS
08/28/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval 5 COLUMNS AS PER DETAIL #1, PAGE S1.1 OK TO POUR COLUMNS (SHADE STRUCTURE AT MAIN ENTRY)
08/17/2012 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection CONTRACTOR CANCELLED
08/02/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval 4 LIGHT POLE COLUMNS.
08/01/2012 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
07/27/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval MAIN ENTRY MONUMENT WALL (EAST AND WEST WALL PORTIONS) 3 COLUMNS (WEST END) OK TO POUR PROGRESS AREAS. MATTE WIRING OVER OPTIC LINES- NW CORNER- MAIN ENTRY OK TO POUR COVER.
07/20/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
COLUMN FOOTINGS AT MEMORIAL PARK AREA OK TO POUR FOOTINGS
07/10/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
07/09/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
8 LIGHT POLE CAISSON FOOTING S OK TO POUR PROGRESS AREAS
06/29/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
06/18/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
WEST PEDESTRIAL WALK-WAY BRIDGE - SLAB ON BRIDGE (#3 REBAR AT 5 3/8" X 10") OK TO POUR PROGRESSS AREA
05/29/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) BRIDGE ? (2) FOR PEDISTRIAN BRIDGE AT SOUTH FO NEW PARKING GARAGE
05/01/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
04/02/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) CULVERT #15, WING WALL FOOTINGS (WYATT ROAD SOUTH) OK TO POUR FOOTINGS
03/30/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
03/28/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) CULVERT WING WALLS AT 6' 6" (WYATT RD) OK TO POUR PROGRESS AREAS
2) SPILL WAY (SW GARAGE AREA) DETAIL "0" PAGE 2.13 STEM WALL NORTH OF HOPI BLDG DETAIL CITY OF TUCSON OK TO POUR PROGRESS AREAS #105
03/19/2012 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED-RAINED OUT
03/12/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
03/12/2012 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
03/08/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 1 LIGHT POLE CAISSON FOOTING-EAST SIDE OF ERICKSON BLDG
12/01/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 4 SWITCH GEAR PADS-OK TO POUR
10/20/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) INFO ONLY