Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T11CM01643
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/28/2012 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
02/27/2012 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* WATER HEATER: 1) FINISH INSULATING HOT AND RETURN PIPING 2) SUPPORT PUMP ON BOTH SIDES MOP SINK: 1) NO VALVES DOWNSTREAM OF A VACCUM BREAKER 2) 1" AIR GAP AT KEG DRAIN 3) PVC REQUIRES PRIMER AND SOLVANT CEMENT. THERE IS NO APPROVED ONE STEP PVC PRIMER/SOLVANT CEMENT 4) REQUIRE APPROVED INSULATION KIT FOR LAV DRAIN 5) LAV REQUIRES MIXING VALVE 6) TOILETS REQUIRE OPEN FRONT SEAT |