Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T11CM01630
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/25/2012 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
12/23/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* ORION AW OK |
|
12/22/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
12/20/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) BOYS TR 120 OK TO COVER |
|
12/19/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) DBL WYE NOT APPROVED FOR HORIZONTAL INSTALL 1/4 NOT APPROVED AT CLEANOUT RISER-WET |
|
12/12/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WEIR OF TRAP MAY NOT BE ABOVE POINT OF VENT 2) COL 3-5, A.1-C3 OK |
|
12/09/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :$ 1) PROVIDE DIRECTIONS AND/OR A CONTACT NUMBER 2) POST YOUR ADDRESS |
|
11/14/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) COLUMN LINE 4.4 TRUNK BLDG DRAIN WITH STUB UPS ONLY BECAUSE OF DEPTH PER YET TO BE REVISED PLAN DATED 11/3/11 CEN CAWTHORNE. TIED INTO NEW SEWER SEPERATE PERMIT WITH AUTHORIZATION TO BE DISCHARGE |