Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
Permit Number - T11CM01609
Inspection Description - PLUMBING - GAS PRESS TEST FNL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/18/2012 | PLUMBING - GAS PRESS TEST FNL | Approved | IVRS - Inspection :* | |
04/16/2012 | PLUMBING - GAS PRESS TEST FNL | Not ready for Inspection | IVRS - Inspection :* 1) NOT INSTALLED PER PLAN. DRAWING SHOWS DECK DRAIN INSTALLED DIRECTLY OVER P-TRAPS 2) FOR THE THIRD TIME ON THIS JOB-FURNCO COUPLINGS ARE NOT ALLOWED INSIDE THE BLDG. PROVIDE A SHIELDED TRANSITION COUPLING 2) PROVIDE PROPER ALIGNMENT AND SLOPE 3) CLEANOUTS REQUIRED AFTER 45 DEGREE 4) DRAINAGE FITTINGS REQUIRED AT VERTICAL TO HORIZONTAL CHANGE OF DIRECTION |