Permit: T11CM01609

Parcel: 13613001U

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
04/18/2012 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
04/16/2012 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection IVRS - Inspection :*
1) NOT INSTALLED PER PLAN. DRAWING SHOWS DECK DRAIN INSTALLED DIRECTLY OVER P-TRAPS
2) FOR THE THIRD TIME ON THIS JOB-FURNCO COUPLINGS ARE NOT ALLOWED INSIDE THE BLDG. PROVIDE A SHIELDED TRANSITION COUPLING
2) PROVIDE PROPER ALIGNMENT AND SLOPE
3) CLEANOUTS REQUIRED AFTER 45 DEGREE
4) DRAINAGE FITTINGS REQUIRED AT VERTICAL TO HORIZONTAL CHANGE OF DIRECTION