Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROOF DRAINS
Permit Number - T11CM01609
Inspection Description - PLUMBING - ROOF DRAINS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/15/2012 | PLUMBING - ROOF DRAINS | Approved | IVRS - Inspection :* | |
02/28/2012 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* | |
02/09/2012 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* | |
02/01/2012 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* 1) 4 ROOF DRAINS ABOVE RAQUET BALL COURTS FROM UPPER ROOF OVER TO LOWER ROOF 2) CONDENSATE DRAINS OK TO INSULATE 3) WATER LINE TO HOSE BIB IN POOL AREA OK TO COVER |
|
01/26/2012 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* 1) RWLS ALONG COLUMN I BETWEEN COLUMNS 6 AND 12 WITH TEST OK |
|
01/24/2012 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* | |
01/20/2012 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* | |
01/09/2012 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* 1) PVC ASTM 2665 SOLID CORE SPECIFIED 2) TEST REQUIRED 3) PVC AND ABS MAY NOT BE INTERMINGLED 4) SUPPORT RISER-SECURE TO WALL 5) CLEANOUT REQUIRED FOR RWL BELOW GRADE 6) SWEEPS REQUIRED ON VERTICAL TO HORIZONTAL CHANGE OF DIRECTION 7) PLASTIC MAY NOT BE DIRECTLY EMBEDDED IN MASONRY-WRAP PENETRATIONS |