Permit: T11CM01609

Parcel: 13613001U

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T11CM01609

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
10/12/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) CORRECTIONS MADE
10/07/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) POST YOUR ADDRESS
2) ABS ASTM F628 INSTALLED, ASTM D 2661 SPECIFIED
3) JUICE BAR MISSING 2" RISER AT 3 COMP SINK AND MISSING VENT AT 3" FD
4) REDLINE ANY CHANGES AND PROVIDE DOCUMENTATION
5) INSTALL SAN TEE FOR FD
6) POINT OF VENT MAY NOT BE BELOW WEIR OF TRAP
7) INSTALL MISSING FS
8) OTHER AREAS INSTALLED AT THIS TIME ARE OK