Permit: T11CM01557

Parcel: 13316030E

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T11CM01557

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/24/2011 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
06/23/2011 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* CLOSET FLANGE RUL 159 OK, RM 137 YOUR PIPE IS TOO LOW WHICH CREATES A ROULING LODGE, PROVIDE PROPER MAKE-UP ON SOLVENT WELD FITTINGS
06/22/2011 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLOSET FLANGE SHALL REST ON FINISHED FLOOR WITH TOP OF FLANGE 1/4" ABOVE FF 316.3.1 AND 1 S #5, 2.3.2
06/15/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) BR SINK CHANGE OF VENTING REQUIRES A REVISION
2) CLOSET FLANGES REQUIRE INSPECTION
3) LETTER FOR USE OF ABS FROM KC MECHANICAL
4) RED LINE CHANGES TO PLAN
06/14/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
06/10/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*