Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM01526

Parcel: 205630510

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/09/2012 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/05/2012 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RAFTER SPECS NEEDED
2) H2.5'S NEEDED PER 6/D1
3) A34'S AND H25 NEEDED PER 3/D1
4) A34'S NEEDED AT BACK LEDGER PER 7/D1
5) COMPLETE ALL DETAILS PER PLAN