Permit: T11CM01521

Parcel: 110091290


Addresses:

2812 N ROSEMONT AV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
06/07/2011 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/24/2011 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSULATE SHEET METAL SLEEVE ABOVE EVAP COIL
2) DUCT IN HALLWAY OK TO SHEETROCK
3) REMOVE ALL DUCT TAPE USED OUTDOORS ON LINE SET OR COVER WITH APPROVED UV RATED TAPE
4) DISCONNECT WIRED BACKWARDS
5) PROVIDE A GFI SERVICE RECEPT FOR CONDENSOR
6) DO NOT USE PLASTIC CONDENSATE HOSE OUTDOORS
7) CLAMP LINE SET TO BLOCK ON ROOF
8) COAT THE ENTIRE EXPOSED LINE SET, NOT JUST THE TOP