Permit: T11CM01520

Parcel: 125170230


Addresses:

15 N ALVERNON WY


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T11CM01520

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/14/2011 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/08/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK TO COVER WALLS
2) FLANGES OK
09/06/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) GAS NOT INSTALLED PER PLAN, NO REVISION ON SITE-OK TO COVER SUBJECT TO REVISED PLAN
2) SUSHI BAR OK TO COVER
3) OK TO INSULATE HOT PIPING
4) CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR
5) HAMMER ARRESTORS REQUIRED ON FAST CLOSING VALVES (URINAL)
08/30/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) AT P-2 VERIFY WASTE IS TO GREASE WASTE, P-2 REQUIRES FULL SIZE CLEANOUT
2) DO NOT COVER ANYTHING UNTIL IT HAS BEEN INSPECTED AND APPROVED
3) SUPPORT ALL STUB OUTS
4) CAP OFF ALL OPEN PIPING
5) TEST ALL PIPING
6) SUPPORT VERTICAL AND HORIZONTAL PIPING