Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T11CM01520
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/14/2011 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
10/17/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) OK TO COVER CWV SINK 2) OK TO COVER FLOOR SINK NEXT TO WATER HEATER |
|
10/14/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) FLOOR SINK IN DINING ROOM NOT INSTALLED PER PLAN, PLAN SHOWS COMBO WASTE AND VENT 2) 2" WASTE FROM FLOOR SINK TO CONNECT HORIZONTALLY TO UNDERGROUND DRAIN. ONE 45 DEGREE OFF SET MAY BE MADE IN ORDER TO KEEP TAIL PIECE LESS THAN 24" LONG. NO VENT IS REQUIRED-NO TEST REQUIRED ON THIS SECTION 3) EXISTING FLOOR SINK AT WATER HEATER HAS NO VENT 4) OK TO COVER GREASE WASTE EXCEPT AT FS. NEXT TO WATER HEATER 5) CWV NOT READY |
|
08/23/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 2-91S AT SUSHI BAR P-2 AND 3P-1 OK TO COVER NEED TO SEE GREASE WASTE TO INTERCEPTOR OK TO COVER RESTROOM RE-ROUGH |