Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2011 | FRAMING | Approved | IVRS - Inspection :* 1) EXHAUST VENTS AT BATHROOMS NEED TO TERMINATE AWAY FROM OPENABLE WINDOWS 2) NEED T & P RELEASE LINE 3) NEED BUBBLE COVER FOR ROOF GFCI |
|
| 06/24/2011 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO LATHE REAR ADDITION 2) PROVIDE ELECTRIC PLAN SHOWING ALL NEW ELECTRICAL WORK DONE IN ? PANEL SCHEDULE 3) APPROVED PLAN REAR ADDITION CALLS FOR 5/8" T-111, CHANGED TO LATHE 4) ENTIRE HOUSE RE-WIRED |
|
| 06/20/2011 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED PERMIT FOR NEW ROOF TOP UNIT 2) NAIL PROTECTION REQUIRED ON ALL CONDUCTORS WITHIN 1 1/4" OF NAILING SURFACE 3) 1" MINIMUM CLEARANCE FOR WATER HEATER VENT THRU ROOF |
|
| 06/01/2011 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CALL IN AFTER INTERMEDIATES ARE COMPLETE |