Permit: T11CM01483

Parcel: 134251710


Addresses:

1101 S LEHIGH DR

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/14/2011 BUILDING - FINAL Approved IVRS - Inspection :*
05/31/2011 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
* NEED TO POTHOLE FOOTINGS FOR INSPECTION
* NEED A LETTER FROM ELECTRICAL CONTRACTOR ON LETTERHEAD THAT ALL WORK IS SAFE AND MEETS CODE MIN.
*NEED TO ATTACH EXISTING RAFTERS TO LEDGER W/A-35 OR LAG BOLTS, 3/8 3 1/2 LONG
*DRYER VENT NEEDS TO BE HARD PIPED AS REROUT TO OUTSIDE WALL
* NEED SFCI PROTECTION ON OUTSIDE RECEPTS