Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM01466

Parcel: 129020040

Inspection Status: Approved

Inspection History: ZONING - FINAL

Date Description Inspector Results Comments
02/04/2014 ZONING - FINAL Approved ALL PREVIOUS ISSUES HAVE BEEN RESOLVED.
12/13/2013 ZONING - FINAL Partial Approval PARTIAL TO REMAIN IN EFFECT TILL APPROVED REVISED OR AS-BUILT DRAWINGS HAVE BEEN PROVIDED NOTING ALL CHANGES THAT HAVE BEEN MADE TO THIS SITE. CURRENTLY A PARKING SPACE IS MISSING ON THE WEST SIDE OF THE SITE, AND THE P.A.A.L. WIDTHS DO NOT MEET THE 24 FEET MINIMUM REQUIREMENT. THE OWNERS REPRESENTATIVES WILL MEET WITH DAVID RIVERA TOO DISCUSS WHAT CHANGES NEED TO BE MADE TO RESOLVE CURRENT ISSUES.
12/11/2013 ZONING - FINAL Partial Approval PARKING AND PAAL ARE NOT PER THE APPROVED PLAN, PAAL IS ONLY 23 FEET AT THIS TIME AND SHOULD BE 24 FEET. CONTACT DAVID RIVERA 837-4957 AND MAKE ALL NECESSARY CHANGES TO THE PLANS PRIOR TO SCHEDULING ANOTHER INSPECTION.
09/23/2013 ZONING - FINAL Partial Approval MET WITH THE ENGINEER OF RECORD AND WALKED THE SITE. THE INSPECTION WILL REMAIN THE SAME TILL THE WORK IS COMPLETED ON THE SITE AS SHOWN ON THE APPROVED PLANS.
08/08/2012 ZONING - FINAL Partial Approval LOOKED AT THE SITE AND HAVE NOTED THE FOLLOWING ITEMS AS BEING INCOMPLETE AT THIS TIME. 1) THE WESTERN PARKING AREA REQUIRES 16 PARKING SPACES, 14 ARE FREE AT THIS TIME. TWO OF THE SPACES ARE NOT USUABLE AT THIS TIME DUE TO WHAT APPEARS TO BE A PARKING LOT LIGHT CONTROLLER AND A TRASH DUMPSTER. THIS NEEDS TO BE ADDRESSED DOWNTOWN WITH THE ZONING SECTION. 2)THE OUTER WESTERN AND EASTERN PARKING AREAS DO NOT HAVE THE REQUIRED PALL WIDTHS OF 24 FEET. DISCUSS WITH THE ZONING DEPARTMENT WHAT MIGHT BE AN ACCEPTABLE FIX FOR EACH OF THESE LOCATIONS. 3) THE WATER HARVESTING BASINS APPEAR TO BE UNDERSIZED FROM WHAT IS SHOWN ON THE APPROVED PLANS. RESIZE THE BASINS TO THE CORRECT SIZE BEFORE THE FINAL. ALSO NONE OF THE ROCK RIP RAP ON FILTER FABRIC HAS BEEN PLACED IN THE FIELD AS SHOWN ON THE APPROVED PLANS.
I HAVE BEEN ADVISED BY THE ZONING DEPARTMENT THAT THE IRRIGATION SYSTEMS SHOULD HAVE BEEN INSTALLED AND SHOULD BE CHECKED PRIOR TO THIS APPROVAL TO ENSURE THAT NO OTHER WORK IS REQUIRED ON THEM. ALSO THE LANDSCAPE PLANS NEED TO BE SUBMITTED FOR REVIEW PRIOR TO THE APPROVAL FOR THIS PERMIT.