Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T11CM01448
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/07/2012 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
11/05/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
11/04/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) AFTER HOURS INSPECTION REQUESTED BY JESSE WITH JE DUNN/BARKER MORRISEY $165.00 TO BE CHARGED TO BARKER MORRISEY 2) BLDG DRAIN REPLACEMENT PER REVISED P-102 WITH CONNECTIONS TO EXISTING 4" ? IN 2 LOCATIONS OK 3) CLEANOUTS AND WATER TESTS OK |
|
11/03/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* NOTE: CODE DOES NOT ALLOW SDR 35 UNDER A BLDG. REPLACE SDR35 PIPING TO CONNECTION WITH APPROVED MATERIAL AT EXISTING CLEANOUT |
|
11/02/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) 10 AM INSPECTION REQUESTED, NOT READY. 12 NOON COURTESY REINSPECTION 2) 8" BLDG DRAIN REPLACEMENT INSALLED PER UNAPPROVED ADDENDUM AND 5.RFI72 3) WATER TEST OK 4) PROVIDE VERIFICATION OF GRADE AND CITY APPROVED PLAN REVISION 5) PLAN INDICATES 74 PERCENT SLOPE AND DOES NOT SHOW THE CODE REQUIRED CLEANOUTS NOT TO EXCEED 100' DEVELOPED LENGTH |
|
11/01/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) GOOD PROGRESS |
|
10/31/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | 1) LOCATE AND ? EXISTING 6" SEWER 2) REVIEWED AUTHORITY TO DISCHARGE |
|
10/28/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
10/21/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) 10" RWL WITHIN BLDG FOUNDATION, WITH TEST OK TO COVER |
|
10/20/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) UNIFORM PLUMBING CODES (SEC. 712) REQUIRES A 10' WATER TEST WITH VISUAL INSPECTION OF EACH JOINT. PLASTIC MAY NOT BE TESTED WITH AIR (IPC 312) |
|
10/18/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE DRAINAGE FITTINGS, USE PRIMER AND HEAVY BODY CEMENT |