Permit: T11CM01413

Parcel: 113010300


Addresses:

1420 E ROGER RD

Inspection Status: Not ready for Inspection

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/14/2011 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) FLEX GETS INSTALLED AFTER CODE APPROVED GAS VALVE
2) CORRECT ALL PREVIOUSLY NOTED CORRECTIONS
3) INSTALLATION SHALL COMPLY WITH YOUR OG 300 PLAN
4) REMOVE CROSS CONNECTION
07/21/2011 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) B-VENT INSTALLED UPSIDE DOWN
2) B-VENT REQUIRED THRU ROOF TO TERMINATION ABOVE COOLER
3) GAS SOV REQUIRES ACCESS
4) ADD SUPPORTS TO PIPING NEAR WATER HEATER CONNECTIONS
5) PROVIDE AN AIR GAP AT T & P TERMINATION INTO DUAL INLET WASHER BOX
6) PROVIDE FLASHINGS AND INSTALL PER LISTING REQUIREMENTS
7) INSULATE IN A WORKMANSHIP LIKE MANOR AS SPECIFIED IN THE INSTALLATION INSTRUCTIONS
8) PATCH NAIL HOLES IN ROOF AND SUPPORT ALL TUBING
9) PROVIDE A CONCRETE OR OTHER APPROVED BASE
10) PROVIDE ACCESS TO DRAIN BACK TANK
11) HAVE A LICENSED ELECTRICIAN INSTALL A CODE APPROVED OUTLET
12) SEAL EXOPSED EDGES OF ENCLOSURE
13) CONTRACTOR SHALL PAY A REINSPECTION FEE FOR FAILURE TO COMPLY WITH CODES AND WORKMANSHIP STANDARDS