Permit: T11CM01351

Parcel: 110120960


Addresses:

5301 E GRANT RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T11CM01351

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
04/02/2012 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
03/15/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) STEM WALL AT SOUTH EAST STAIRWELL #1-DETAIL #5, PAGE #402 OK TO GROUT PROGRESS AREAS
02/29/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 6 COLUMNS: DRY PACK-EAST ENTRY AREA
02/28/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELECTRIC ROOM CMU WALLS AT 8' OK TO GROUT PROGRESS AREA
02/27/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELECTRIC ROOM AT 4' OK TO GROUT
01/13/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) STORAGE ROOM GL: B/2-3; B.5/2-3 OK TO GROUT
01/04/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEVATOR SHAFT TOPPED OUT AT 62'; ELEVATOR ROOM, ELECTRIC ROOM, RISER ROOM TOPPED OUT-OK TO GROUT PROGRESS AREAS
01/03/2012 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
01/03/2012 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 56' LIFT ON ELEVATOR SHAFT
12/30/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/29/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) OK TO GROUT ELEVATOR SHAFT AT 50' PLUS OR AT SOUTH EAST CORNER
2) SPECIAL INSPECTION REPORT ON SITE AND REVIEWED
3) CONTRACTOR PAID FOR AFTER HOURS INSPECTION $165.00 FROM APA ACCOUNT-SEE LEERAY
12/27/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
12/27/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEVATOR SHAFT AT SOUTH EAST CORNER AT 44' PLUS OR-OK TO GROUT GRIDS D.7 & E/5.5 & 6
2) AFTER HOURS INSPECTION PAID BY CONTRACTORS APA ACCOUNT $165.00-SEE RAY MAJUTA FOR PAYMENT
12/22/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/21/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 36' ON SHAFT
2) AFTER HRS INSPECTION $165.00 FEE-SEE LEERAY ABOUT PAYMENT
12/20/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/19/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 26' LIFT ON ELEVATOR
12/19/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
12/15/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
12/14/2011 REINFORCED MASONRY PRE-GROUT Cancelled CANCELLED PER CONTRACTOR CHRIS #400-3915
12/14/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER OFFICE
12/13/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection 1) CONTRACTOR CANCELLED DUE TO RAIN
12/12/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
12/09/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEVATOR SHAFT AT 8'-18' AFFE OK TO GROUT PROGRESS AREA
12/08/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEVATOR WALLS AT 12' AFFE: OK TO GROUT PROGRESS AREAS
12/07/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEVATOR SHAFT WALLS AT 8' 8"-OK TO GROUT PROGRESS AREAS-18 COLUMNS: DRY PACKED
12/06/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST LIFT AT 0"-48" AFFE-OK TO GROUT ELEVATOR PIT AREA
12/05/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS AT 48" AFFE, ROOMS #9, 10 AND 10A-OK TO GROUT PROGRESS AREAS