Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/31/2011 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 08/23/2011 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* PROVIDE A SPLIT BOLT CONNECTOR OR A LISTING FOR THE WIRE NUT USED FOR COPPER TO ALUMINUM CONDUCTORS. EVERYTHING ELSE IS OK. |
|
| 08/18/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM #2 NOT CORRECTED-CANNOT REMOVE WATER HEATER 2) USE THE PROPER SPLIT BOLT CONNECTOR FOR NEUTRAL COPPER CONDUCTOR TO ALUMINUM CONDUCTOR INSIDE DISCONNECT ON PATIO 3) SEPERATE NEUTRALS AND GROUNDS IN SUB PANEL IN FURNACE CLOSET |
|
| 07/19/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |