Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM01308

Parcel: 140552360

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/30/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/29/2011 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE PRIOR LIST
11/17/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) AB'S AT PLATE JOINTS
2) CHECK ALL SHEARWALL NAILING 5 6" + 12"
3) NAIL OSB AT DBL STUDS 6" ON CENTER
4) DIAPHRAM NAILING PER DETAIL 201/R.3
5) CHECK SHEAR TRANSFER NAILING AT GARAGE/KITCHEN WALL
6) SHIM 3 PT BEARING C02 A TRUSSES
7) MISSING CLIPS C02 A TRUSSES
8) A0? AND A04 SWITCHED PER LAYOUT