Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2011 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 05/23/2011 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/05/2011 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FLUE PIPE NOT SUPPORTED 2) DUCT JOINTS NOT SEALED 3) PVC NOT PRIMERED 4) PVC NOT SUPPORTED 5) PROVIDE APPROVED BUSHING OR GROMMET WHERE CONTROL WIRING PENETRATES FURNACE CABINET 6) T-STAT WIRE EXPOSED TO EXTERIOR IS TO BE IN PROTECTIVE CONDUIT 7) PROVIDE PROPER FUSE SIZE IN CONDENSOR DISCONNECT 8) LINE SET INSULATION TO BE COATED PER MANUFACTURERS INSTALLATION INSTRUCTIONS, MIL TAPE NOT APPROVED FOR THIS APPLICATION 9) CONDENSATE PIPE TO TERMINATE 6" ABOVE GRADE AND 90 DEGREE AWAY FROM STRUCTURE |