Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2011 | BUILDING - FINAL | Approved | IVRS - Inspection :* 1) CLAMP TUBING 2) PLUMBERS TAPE NOT A LISTED PIPE SUPPORT 3) NEW WATER HEATER REQUIRES A SEDIMENT TRAP |
|
| 06/09/2011 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) A GAS FLEX MAY NOT BE REUSED 2) PROVIDE A CORRECT ELECTRICAL INSTALLATION 3) PROVIDE AN APPROVED OG 300 PLAN FOR THIS INSTALLATION 4) CORRECT VENTING OF NEW GAS WATER HEATER 5) ALL PIPING REQUIRES SUPPORT INDEPENDENT OF APPLIANCE CONNECTIONS 6) ALL JOINTS OF COPPER TUBING SHALL BE REAMED, ALL EXCESSIVE FLUX SHALL BE REMOVED |
|
| 05/06/2011 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE VENT AND CORRECT DRIPPING RELIEF VALVE ON EXISTING GAS WATER HEATER 2) REPAIR HOLES IN ROOF, SUPPORT TUBING WITH BLOCKS 3) YOU HAVE CONFLICTING PLANS. PROVIDE ONE ISOMETRIC DRAWING FOR THIS SYSTEM |