Permit: T11CM01232

Parcel: 141316850


Addresses:

7735 E JACK OAK RD

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/24/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/22/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SILL PLATE EXTERIOR SHEARWALL FASTENING PER PLANS
2) CLIP TRIMMER STUDS UNDER GIRDER
3) NAIL OFF BOTTOM PLATE SHEAR AT ENTRANCE ON GARAGE SIDE
4) NAIL OFF SHEAR ABOVE GARAGE DOOR
06/21/2011 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER JOHN