Permit: T11CM01206

Parcel: 135082360

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
06/13/2011 MECHANICAL - FINAL Approved IVRS - Inspection :*
06/06/2011 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
EXTEND VENT IN CONDESATE DRAIN ABOVE DRAIN PAN IN COIL CABINET. PROVIDE SEDIMENT TRAP AT WATER HEATER. LINE SET STILL MISSING ARMFLEX.
T + P DRAIN CANNOT BE REDUCED FROM 3/4" I.D. PROVIDE ROOF JACK + FITTING FOR CONDENSATE TERMINATION.
06/01/2011 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A PROTECTIVE COATING ON EXPOSED ARMAFLEX AND REMOVE ANY DUCT TAPE USED OUTDOORS
2) CONDENSOR OVERFUSED
3) PROVIDE SEDIMENTS AT FURNACE AND WATER HEATER
4) PVC CANNOT BE WITHIN 6" OF SINGLE WALL VENT CONNECTOR
5) PROVIDE AN OVERFLOW SENSOR
6) TERMINATE T & P DRAIN SEPERATELY FROM CONDENSATE
7) DO NOT USE FLEX COPPER IN T & P DRAIN
8) EXTEND CONDENSATE VENT ABOVE DRAIN PAN
9) COVER ALL SECTIONS OF SUCTION LINE WITH ARAMFLEX
10) PROVIDE 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS 11) REMOVE ALL TAPE