Permit: T11CM01173

Parcel: 125090230


Addresses:

2545 E BROADWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/31/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
05/26/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ICE BIN DRAIN-PVC NOT PRIMED OR SOLVENT WELDED OPEN DRAIN
2) VENT FITTINGS BELOW THE FLOOD RIM TO BE DRAINAGE TYPE
3) WHERE A VENT CONNECTS TO A HORIZONTAL DRAIN IT SHALL HAVE ITS INVERT TAKEN OFF ABOVE THE DRAINAGE CENTER LINE DOWN STREAM OF THE TRAP BEING SERVED
4) ICE MAKER REQUIRES BACKFLOW PROTECTION
05/24/2011 PLUMBING - FINAL Not ready for Inspection 1) EACH FIXTURES TRAP SHALL HAVE A CONNECTING VENT CONNECTED DOWNSTREAM OF THE TRAP
2) ONLY ONE TRAP ON A TRAP ARM
3) USE OF AIR ADMITTANCE VALVES SHOULD BE OK
4) AIR GAPS STRICKLY ENFO
5) CONNECT ICE MAKER
05/18/2011 PLUMBING - FINAL Cancelled CANCELED PER CONTACTOR JOHN ALLEN #975-6162
05/18/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) DOOR LOCKED